Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Ortop Mex ; 37(3): 152-158, 2023.
Artigo em Espanhol | MEDLINE | ID: mdl-38052436

RESUMO

INTRODUCTION: all-in meniscal suture devices have evolved and simplified meniscal repair. In this study we will formulate the following research questions: what is the rate of survival and failure? What are the risk factors associated with failure? And what are the functional results after meniscal repair surgery? MATERIAL AND METHODS: ambispective study from 2001 to 2021 of patients with repairable meniscal injury with all-in meniscal suture devices. The survival and failure ratio were obtained with the Kaplan-Meier test, the risk factors associated with meniscal suture failure were assessed with the logistic regression test, and the pre- and post-surgical functional results were estimated with the test. t-Student. RESULTS: in 20 years of follow-up of 316 menisci repaired with all-in meniscal sutures, a survival rate of 95.9% was obtained. The absence of injury to the anterior horn of the meniscus was shown to be a protective factor [OR = 0.12], together with not practicing impact sports [OR = 0.2]. Post-surgery IKDC and Tegner-Lysholm results were shown to be very good to excellent (p < 0.0001). CONCLUSION: all-in meniscal suture devices are and will continue to be front-line weapons in the repair of meniscal tears. In 20 years of follow-up, a lower failure rate was evidenced, associated with excellent functional results.


INTRODUCCIÓN: los dispositivos de suturas meniscal todo adentro han evolucionado y simplificado la reparación meniscal. En este estudio formulamos las siguientes preguntas de investigación: ¿cuál es la tasa de supervivencia y falla?, ¿cuáles son los factores de riesgo asociado a falla? y ¿cuáles son los resultados funcionales posterior a la cirugía de reparación meniscal? MATERIAL Y MÉTODOS: estudio ambispectivo desde el 2001 al 2021 de pacientes con lesión meniscal reparable con dispositivos meniscales de sutura todo adentro. La razón de supervivencia y falla se obtuvo con el test de Kaplan-Meier, los factores de riesgo asociado con falla de la sutura meniscal se valoraron con el test de regresión logística y los resultados funcionales pre y postquirúrgicos fueron estimados con la prueba t-Student. RESULTADOS: en 20 años de seguimiento de 316 menisco reparados con suturas meniscal todo adentro se obtuvo que la razón de supervivencia de 95.9%. La ausencia de lesión del cuerno anterior del menisco se mostró como un factor protector [OR = 0.12], junto a la no práctica de deportes de impacto [OR = 0.2]. Se mostraron resultados del IKDC y Tegner-Lysholm posterior a la cirugía de muy buenos a excelentes (p < 0.0001). CONCLUSIÓN: los dispositivos de sutura de meniscal todo adentro son y seguirán siendo armas de primera línea en la reparación de las roturas meniscales. En 20 años de seguimiento se evidenció una menor tasa de falla, asociados con excelentes resultados funcionales.


Assuntos
Meniscos Tibiais , Lesões do Menisco Tibial , Humanos , Artroscopia , Meniscos Tibiais/cirurgia , Estudos Retrospectivos , Técnicas de Sutura , Suturas , Lesões do Menisco Tibial/cirurgia
2.
Acta Ortop Mex ; 33(4): 247-251, 2019.
Artigo em Espanhol | MEDLINE | ID: mdl-32246596

RESUMO

INTRODUCTION: Dislocation of the acromioclavicular joint is a common injury, which is observed mainly in young adults; indications for surgical management and the most appropriate technique remain controversial. MATERIAL AND METHODS: We present a surgical technique, whose objective is the anatomical reconstruction of the coracoclavicular ligaments with autologous semitendinous graft, without tunnels in the collarbone and without fixing devices. RESULTS: This technique is reliable for stabilizing the joint in the short term and we consider that it could neutralize the anteroposterior translation of the distal collarbone. DISCUSSION: Studies are required to report on functional and radiological results, with the use of this surgical technique so that we can then point out that it has advantages over other therapeutic options existing today.


INTRODUCCIÓN: La luxación de la articulación acromioclavicular es una lesión común que se observa principalmente en adultos jóvenes. Las indicaciones para el manejo quirúrgico y la técnica más adecuada siguen siendo controvertidas. MATERIAL Y MÉTODOS: La técnica quirúrgica presentada se basa en una reconstrucción anatómica de los ligamentos coracoclaviculares mediante un injerto autólogo del tendón del semitendinoso, sin túneles en la clavícula y sin ningún dispositivo de fijación, ya que se utilizan sólo suturas. RESULTADOS: Se logró la reconstrucción anatómica y biológica de los ligamentos coracoclaviculares, la cual utilizó un autoinjerto tendinoso sin ningún dispositivo de fijación adicional, lo que minimiza el riesgo de complicaciones relacionadas con el uso de tornillos o implantes metálicos. DISCUSIÓN: Este procedimiento es un método eficaz y confiable para estabilizar la articulación. Se requieren estudios que informen los resultados funcionales y radiológicos con el empleo de esta técnica quirúrgica para entonces poder asegurar que tiene ventajas sobre otras opciones terapéuticas existentes en la actualidad.


Assuntos
Articulação Acromioclavicular , Músculos Isquiossurais , Luxações Articulares , Tendões , Articulação Acromioclavicular/cirurgia , Autoenxertos , Clavícula , Humanos , Luxações Articulares/cirurgia , Ligamentos Articulares , Tendões/transplante , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...